Tarp-assisted cooling as a method of whole-body cooling in hyperthermic individuals
- UNCG Author/Contributor (non-UNCG co-authors, if there are any, appear on document)
- William M. Adams, Assistant Professor (Creator)
- Institution
- The University of North Carolina at Greensboro (UNCG )
- Web Site: http://library.uncg.edu/
Abstract: Study objective: We investigated the efficacy of tarp-assisted cooling as a body cooling modality. Methods: Participants exercised on a motorized treadmill in hot conditions (ambient temperature 39.5°C [103.1°F], SD 3.1°C [5.58°F]; relative humidity 38.1% [SD 6.7%]) until they reached exercise-induced hyperthermia. After exercise, participants were cooled with either partial immersion using a tarp-assisted cooling method (water temperature 9.20°C [48.56°F], SD 2.81°C [5.06°F]) or passive cooling in a climatic chamber. Results: There were no differences in exercise duration (mean difference=0.10 minutes; 95% CI –5.98 to 6.17 minutes or end exercise rectal temperature (mean difference=0.10°C [0.18°F]; 95% CI –0.05°C to 0.25°C [–0.09°F to 0.45°F] between tarp-assisted cooling (48.47 minutes [SD 8.27 minutes]; rectal temperature 39.73°C [103.51°F], SD 0.27°C [0.49°F]) and passive cooling (48.37 minutes [SD 7.10 minutes]; 39.63°C [103.33°F], SD 0.40°C [0.72°F]). Cooling time to rectal temperature 38.25°C (100.85°F) was significantly faster in tarp-assisted cooling (10.30 minutes [SD 1.33 minutes]) than passive cooling (42.78 [SD 5.87 minutes]). Cooling rates for tarp-assisted cooling and passive cooling were 0.17°C/min (0.31°F/min), SD 0.07°C/min (0.13°F/min) and 0.04°C/min (0.07°F/min), SD 0.01°C/min (0.02°F/min), respectively (mean difference=0.13°C [0.23°F]; 95% CI 0.09°C to 0.17°C [0.16°F to 0.31°F]. No sex differences were observed in tarp-assisted cooling rates (men 0.17°C/min [0.31°F/min], SD 0.07°C/min [0.13°F/min]; women 0.16°C/min [0.29°F/min], SD 0.07°C/min [0.13°F/min]; mean difference=0.02°C/min [0.04°F/min]; 95% CI –0.06°C/min to 0.10°C/min [–0.11°F/min to 0.18°F/min]). Women (0.04°C/min [0.07°F/min], SD 0.01°C/min [0.02°F/min]) had greater cooling rates than men (0.03°C/min [0.05°F/min], SD 0.01°C/min [0.02°F/min]) in passive cooling, with negligible clinical effect (mean difference=0.01°C/min [0.02°F/min]; 95% CI 0.001°C/min to 0.024°C/min [0.002°F/min to 0.04°F/min]). Body mass was moderately negatively correlated with the cooling rate in passive cooling (r=–0.580) but not in tarp-assisted cooling (r=–0.206). Conclusion: In the absence of a stationary cooling method such as cold-water immersion, tarp-assisted cooling can serve as an alternative, field-expedient method to provide on-site cooling with a satisfactory cooling rate.
Tarp-assisted cooling as a method of whole-body cooling in hyperthermic individuals
PDF (Portable Document Format)
320 KB
Created on 3/3/2020
Views: 566
Additional Information
- Publication
- Annals of Emergency Medicine. 2017;69(3):347-352
- Language: English
- Date: 2017
- Keywords
- exertional heat stroke, hyperthermia, tarp-assisted cooling, sports medicine