Kinematic analysis of functional lower extremity perturbations
- UNCG Author/Contributor (non-UNCG co-authors, if there are any, appear on document)
- Anthony S. Kulas (Creator)
- David H. Perrin, Former Provost and Executive Vice Chancellor (Creator)
- Thomas C. Windley (Creator)
- Randy J. Schmitz, Associate Professor (Contributor)
- Sandra J. Shultz, Professor and Chair (Contributor)
- Institution
- The University of North Carolina at Greensboro (UNCG )
- Web Site: http://library.uncg.edu/
Abstract: Background. Sudden changes in direction on a single weight-bearing-limb are commonly associated with injury to the lower extremity. The purposes of this study were to assess the between day reliability of hip, knee, and ankle kinematic displacements achieved with internal and external femur-on-weight-bearing-tibia rotation perturbations and to determine the effect of these perturbations on three dimensional hip, knee and ankle kinematics.
Methods. Twenty recreationally active, healthy college students with no history of significant orthopedic injury (10 male, 10 female) were subjected to a forward and either internal or external rotary perturbation of the trunk and thigh on the weight-bearing-tibia while three dimensional kinematics were simultaneously collected. The protocol was repeated 24–48 h later to assess reliability.
Findings. External perturbations resulted in significant internal rotation (IR) of the tibia on the femur (mean 7.3 (SD 3.9°)) and IR of the femur on the pelvis (mean 6.8 (SD 5.4°)) (P < 0.05). Internal perturbations resulted in significant external rotation (ER) of the tibia on the femur (mean 6.8 (5.9°)) and ER of the femur on the pelvis (mean 10.7 (SD 96.1°)) (P < 0.05). Additionally the external perturbation results in a significantly greater knee valgus (mean 3.6 (SD 2.2°)) position while the internal perturbation results in a significantly greater knee varus position (mean 2.3 (SD 3.5°)) (P < 0.05). External perturbation hip and knee total joint displace-ments revealed moderate to strong reliability (Intraclass Correlation Coefficient2,k = 0.67–0.94) while internal perturbations revealed slightly higher Intraclass Correlation Coefficients2,k(0.80–0.96).
Interpretation. The lower extremity perturbation device provides a consistent external and internal perturbation of the femur on the weight-bearing-tibia. The observed transverse and frontal plane kinematics are similar to motions observed during cross-over and side-stepping tasks.
Kinematic analysis of functional lower extremity perturbations
PDF (Portable Document Format)
354 KB
Created on 1/1/2004
Views: 2151
Additional Information
- Publication
- Clinical Biomechanics, 19:1032-1039
- Language: English
- Date: 2004
- Keywords
- Knee, Hip, Injury mechanism